Gas generator set 50Hz

Fuel gas type:

 

Natural gas, biogas, landfill gas, oil field gas

Genset working condition:

Acceptable working conditions:

Ambient temperature : 0°C~+40°C   

(antifreeze, oil and water heater needed for below 0°C)

Relative humidity:lower 90%(20°C)

Altitude:lower than 500m, if more than 500m, every increase 100m, the power decrrease 1%

Normal working conditions:

Genset can run at rated power on the conditions:

Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%

Standard Scope of Supply:

1.Brand new gas engine, 90% parts from Cummins engine body such as crank shaft, cam shaft, piston, cylinder head;

2.Brand new brushless alternator

Rating: 3 phases 4 lines. 400/230V, 50 HZ , 1500rpm, 0.8PF, IP22-23, Insulation class H;

3.Radiator for 40°C/50°C ambient temperature;

4.Ignition system adopted USA ALTRONIC;

5.Emergency stop mounted;

6.Battery,Battery cable and Battery charger;

7.Standard tool box;

8.Standard Accessory for installation (include bellows,silencer,flange,asbestos pad,Anti-rust water,screw )

9.Gas Train include Regulator valve,Electromagnetic Valve, Fire arrestor,Ball Valve (Chinese brand)

1. Camda gas generator set are developed and researched on the base of Cummins engine. 80% spare parts of Cummins diesel engine can be used for these biogas gensets. Customers can buy the parts from local Cummins agent. It greatly save maintenance cost and time.
 
2.For our ignition system, we use original America Altronic, the ignition time is very exact and the ignition power is big enough.
 
3. We research and develop the spark plug, the lifetime is more than 3000 hours, but for most Chinese spark plug, the life time is about 500-800 hours.
 
4. For our gas intake system, we use the world most advanced solenoid valve like German Dungs and  Italian Elektrogas. These solenoid valves can open gradually and shut off in very short time, which can protect the engine very well.
 
5.For our speed governing system, we use the speed governor and actuator from Switzerland, this system is more stable and reliable, it can react very fast when the load increase or decrease. The German MAN gas engine also use this system.
 
6. We also develop and research the automatic air-fuel ratio system, it can adjust the biogas and air flow rate to the engine automatically when the methane content in the biogas change.
7. Camda made a research to the biogas engine since 2005, until 2010 we began to sell, we have strong technical support team. And our gensets have been sold all over the world.

 